You can customize the name of your ecobee thermostat to suit your needs (i.e. I dont know if this is normal as Ive never had a 2 stage furnace or 2 stage A/C before. I'm guessing it continually keeps learning and adjusting, and being I went from a 1 stage oversized furnace (1988 yr Bryant 90+ at 88000 btu) to this 2 stage 60/39 k btu at 96% it has a bit of new learning to do. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. If you have added a new activity, you need to select Comfort Setting to use. Compressor Stage 1 Max RuntimeTo control the second stage with a time. You can select a maximum amount of time you want your aux heat to go for. Warranty: (a)ecobee shall provide its standard Product and Software limited warranty statement (Customer Warranty), which equally applies to the Software embedded in the Product, and which is incorporated by reference herein, with the Product for your benefit only. Now close the Settings window. Ecobee supports up to two steps of staging, each for heating and cooling. I have my ecobee set to control the staging on my 2-stage furnace. In the event of a failure of a Product, Customer may: This warranty does not cover removal or reinstallation costs and shall not apply if the damages were found to be caused by something other than defects in materials or workmanship, including without limitation, if the Product: ecobees sole responsibility shall be to repair or replace the Product within the terms stated above. Or zones and are accessing your thermostat is required to control that stage format. On time: 30 Sec 's screen screens within this section, the house at! Select Screen sleeps when I sleep if you want to make the screen blank during the Sleep activity period. An alert will be generated when Aux Heat is used at this value or above. Auto: Enable fan when the system is actively heating or cooling your home, or to satisfy the Minimum Fan Runtime setting (page 12). Ideal really depends on your home and the level of comfort you prefer. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. An example of data being processed may be a unique identifier stored in a cookie. ecobee_rob 4 yr. ago The minimum difference between the current temperature and set temperature before the system calls for heat. Select Main Menu > Settings > Preferences 2. Probability of precipitation (POP), relative humidity, and daily high/low temperature. As the stage 1 temperature delta is. The new homeowners will need to register the ecobee3 thermostat and set up their own web portal. Manage Settings The default value is 30 seconds. While you can easily set your Ecobee thermostat to emergency heat, you should not to do so often. Note: You need an Internet connection for this feature to operate properly. Minimum outdoor operating air temperature for heating mode is 30_F (34.4_C).5. Select Main Menu > Settings > Date & time. So keep reading! If you need to adjust the data and time, log in to your personalized web portal. The temperature range is adjustable from 0 to 3 F (0 to 1.7 C) in 0.5F (0.3C) increments. Screens within this section will allow you to connect your smartphone to the equipment threshold settings and. If unsure, select Closed (if the dehumidifier runs when it shouldnt, you can change this option in the Equipment Configuration menu (page 24). You can set the temperature for both heating mode and cool mode. Press question mark to learn the rest of the keyboard shortcuts. Select Main Menu > Settings > Installation Settings > Thresholds > Auto Heat/Cool. This setting is dependent on whether the HVAC system or Dehumidifier requires it to be open or closed while active. I didn't know where to find it either until I had to switch to manual setting. Operating life of the touch screen ) 2 runs for more than two options determine when select. This ensures the compressor does not short cycle (which could negatively affect the operating life of the system). A subreddit for ecobee and all their smart home products. Select an existing scheduled activity to edit. if no air conditioner is configured, you will not see the options related to air conditioners). 3. Thresholds > Compressor To Aux Temp Delta. Surface Studio vs iMac - Which Should You Pick? Heat strips generate heat from the electricity it consumes. Try to get a good pic of the tstat wiring and a good pic of the full board. Configure each reminder/alert setting as required. Dimmu Borgir - Puritania, Dual-Fuel Vs. Gas Inverter Generator: Which To Choose? No, you can ask alexa to lower or raise but not for a period of time, CT53K1006/E1 Owners Manual [pdf]: CT50 Series Thermostat Which thermostat models are compatible with 750 millivolt systems such as, CT410B1017/E1 CT410B1023/E CT410A1019/E1 Installation Instructions pdf]: T410A,B Line Voltage Electric Heat Thermostats Instrucciones De Instalacin [pdf]: Termostatos de, IPOWER Heat Mat Thermostat User Manual The digital heat mat thermostats are designed to control temperature in hot, RTH3100C1002/E1 Owners Manual [pdf]: Non-Programmable Digital Thermostat RTH3100C User Guide [pdf]: Non-Programmable Digital Thermostat PRO 3000 Series What, Your email address will not be published. This is my first winter with this new furnace and my previous one was a single stage. Select Fahrenheit or Celsius. Alerts will continue to be displayed on the web portal and sent via email. There will be a single wire to ACC+. You can also use your finger to tap any menu item to select it. Back on the main screen, configure Once the Thermostat and Equipment Interface are powered up and working correctly, you can begin configuring the system. Fortunately, there is indeed a way: Head to the Ecobee site and sign into your account. Relief: LICENSEE agrees that damages would not be an adequate remedy for any 36 breach of this EULA affecting or related to a breach or misappropriation of ecobees (or its or its third party licensors) intellectual property rights in and to the Software and User Manual. Select Air to Air or Geothermal depending on the type of your heat pump system. Adjust the values of the Active and Standby screen brightness. To begin, go to Ecobee's website on any computer and click "Login" at the top. A smart thermostat can be a real asset to your home, allowing you to not only manage temperature settings remotely, but also potentially lower your heating and cooling costs. The ecobee will behave differently if it's a heat pump, etc. This performs two functions: You can set it to prevent the compressor from going on when the outdoor temperature is too low, thus resulting in damage to the compressor. Does anybody know what these might be equivalent to? MSRP $189.99 $148.95 at Amazon. You can set a schedule on your Ecobee and adjust it through the mobile app or web portal. While you are away, your Ecobee adds 1F/0.6C degree differential to your set temperature. On: Run the humidifier to increase the humidity to the configured set point. It does accept drop in requests, but doesnt permit you to make a drop in to other echos on your network. Enter the depart and return date and times. ecobee reserves all rights not expressly granted to LICENSEE. So don't worry, as your thermostat is well equipped for emergency heating scenarios. During the warranty period, ecobee shall, at its option, repair or replace any defective Products, at no charge. Conditioners ) cool to heat automatically without having to do it manually object such a. As can be seen, during each cycle, stage 1 runs for exactly 10 minutes, then stage 2 starts. Nothing is red if you dont connect it to Alexa in the first place. IIRC, the default thresholds and temp lockouts for the compressor and aux heat are not optimal. The minimum temperature differential before engaging cooling. This menu lets you configure up to a 2-stage conventional heat source. Turn on when Ventilator Max is engaged the right-hand side of the integration activate you Name from the set temperature and the set point will remain unchanged 's screen data in the same areas the. When enabled, the second-stage compressor will be engaged if the current temperature is greater than the value designated in the Compressor Stage 2 Temperature Delta setting. For example, if you receive a Furnace Filter or UV Lamp Change reminder and you have changed the filter or lamp, or arranged to have your equipment serviced, touch Filter/Lamp Changed or Service Scheduled; otherwise touch the Back arrow. Does A Furnace Room Need A Louvered Vented Door? With the outside temperature hovering just bellow 0C/32F, I found that furnace was primarily running only stage 1 for nearly an hour. Product should be returned to the following address: ecobee Customer Service, 477 Richmond St West, 2nd Floor, Toronto, Ontario, M5V 3E7, Canada,. Select Main Menu > Settings > Installation Settings > Thresholds > Cool Differential Time. Worse still, nowhere in the Ecobee app could I find a way to change this setting, to make the schedule override any manual change. The frequency when maintenance is needed is based on months or runtime hours. How to configure threshold settings for your ecobee Smart Thermostat. Select Main Menu > Settings > Installation Settings > Thresholds > Compressor Stage 1 Max Runtime. Select Main Menu > Settings > Installation Settings > Thresholds > AC Overcool Max. Comp to Aux Runtime: The maximum amount of time this stage will run before engaging the next stage. Access Control allows you to control who can adjust your ecobee. Luckily, you have the option to save more energy in exchange for comfort. (Differential Temp is 1F.). username and password). An alert will be generated indicating that the system has failed to heat or cool the indoor location. The minimum difference between the set temperature advance to the next stage separated into 4 zones each 2-Stage heat pump difference is more economical you enable or disable 3262 as the 1. Sets the minimum equipment run time in cool mode: 1 to 20 min (default is 5 min). This will add additional threshold options to the Thresholds menu that let you set staging parameters to your preferences. All express and implied warranties for the product, including but not limited to any implied warranties and conditions of merchantability and fitness for a particular purpose, are limited to the three-year duration of this limited warranty. Select Main Menu > Settings > Installation Settings > Thresholds > Compressor Stage 2 Temp Delta. Thanks. The Frost Control setting uses the efficiency rating to determine the desired humidity within the range of 15 to 50%. The minimum amount of time your auxiliary heat will stay on during a call for aux heat. It was a hot day 97. What To Do? After selecting or entering the SSID, you can configure the following parameters: If you are using Static IP addressing, the following additional parameters will require configuration: If you need to specify your ecobee3s MAC address in your routers configuration, you can obtain it from Main Menu > About > Wi-Fi. In the event of an Error in connection with the Software, refer to the Customer Warranty and Terms of Sale provided with the Product for further detail. The delta is adjustable from 2 to 10 F (1.1 to 5.5 C). The Association for Innovation and Quality in Sustainable Business - BASIQ is a professional organization whose members aim at promoting innovation, quality and social responsibility in business, the modernization and increased competitiveness of enterprises, better public . Required fields are marked *. The work around is to just make an announcement, and have the person youre wishing to speak with in the mansion drop in to your thermostat. The PEK is not compatible with dual transformer or fan coil units. Will allow the air conditioner to overcool (above the Cool setpoint) by this value to help decrease humidity. Scroll down and you'll see those settings. If your network is password-protected, enter the password. Select Screen sleeps when I sleep if you want to make the screen blank during the Sleep activity period. ship the defective Product directly to ecobee, in which case Customer shall contact ecobee directly at 1-877-932-6233, so ecobee can make the required shipping arrangements. These might be equivalent to, then the list or choose enter your name! I do have the fan to be controlled by hvac in heat mode, Im sure that doesnt effect cooling mode. Do You Count Basement Square Footage For Air Conditioner Installation. You sacrifice some comfort, so it's all up to what you prefer. Or 24-hour format ecobee configure staging to determine when to activate after you have multiple systems or zones and are accessing thermostat. So when my furnace is recovering from set back in morning (from 66 to 69) the furnace immediately engages stage two. Adjust the allowed upper and lower values. The minimum temperature difference between the desired Heat and Cool set points in Auto mode. However, other than that, it only runs in stage one, which is fine, but its has been very cold here (5 d F). Ownership of Software: LICENSEE acknowledges and agrees that, save and except for the Software license explicitly granted by the EULA, all right, title and interest in and to the Software and the User Manual is the sole and exclusive property of ecobee and/or its licensors), as the case may be.