1stQ Basis Z hydrophob (+) A=118.0 a0=1.32 a1=0.40 a2=0.10 pACD=5.46 sf=1.70 A=118.9 A=119.2 97 [271]
Physicians considering lens implantation under any of the following circumstances should weigh the potential risk/benefit ratio: Patients in whom the posterior capsule is ruptured, zonules are damaged, or primary posterior capsulotomy is planned. Hexavision HQ-203HEP (+) A=118.2 a0=1.14 a1=0.40 a2=0.10 pACD=5.28 sf=1.52 A=118.5 A=118.8 151 [202]
The .gov means its official. Polytech Polylens A60 A=118.0 a0=0.85 a1=0.40 a2=0.10 pACD=5.05 sf=1.31 A=118.2 A=118.6 57 [35]
Constants to download: Biometer: all Haag-Streit Lenstar Haag-Streit Lenstar LS900 Heidelberg E. Anterion Nidek AL-Scan Oculus Pentacam Okulix Tomey OA-2000 Topcon Aladdin Zeiss IOLMaster Zeiss IOLMaster 500 Zeiss IOLMaster 700 Ziemer GALILEI G6 (*****): results based on patients with small mean anterior chamber depth: 2.78 +/- 0.35 mm
[229]: data by Dr.J.Wolff, Heppenheim, Germany
Constants for IOLs characterized by '(Japan)'are based on results for Japanese eyes, which tend to be somewhat longer
Nidek Nex-Acri AA A=119.5 a0=1.56 a1=0.40 a2=0.10 pACD=5.73 sf=1.95 A=119.2 A=119.7 167 [18]
2019;45:1490-1497. The Open University is incorporated by Royal Charter (RC 000391), an exempt charity in England & Wales and a charity registered in Scotland . [134]: data by Dr.Chr.Chassain, Montpellier, France
[138]: data by Dr.E.Tahmaz, Erkelenz, Germany
Kowa Avansee AN6K A=118.7 a0=1.57 a1=0.40 a2=0.10 pACD=5.64 sf=1.85 A=119.0 A=119.3 100 [248]
[121]: data by Daniel Badoza MD, Buenos Aires, Argentina
Moss Vision Optiflex MOHF-D012 A=118.5 a0=0.95 a1=0.40 a2=0.10 pACD=5.16 sf=1.43 A=118.4 A=118.6 49 [369]
[133]: data by Keith Kellum, MD, Houma, LA, USA
[349]: data by Dr.Dhaval S. Modi, Ahmedabad, India
[394]: data by Dres Scherer,Lojewsky.
[326]: data by Dr. Paul O'Brian, Dublin, Ireland
If optimized lens constants are not available, these should be considered as only a starting point. [74]: data by Dr.H.Kreinberger, Gera, Germany
A=118.1 a0=1.53 a1=0.40 a2=0.10 pACD=5.75 sf=1.96 A=119.2 A=119.6 68 [53]
Oculentis LS-313Y A=118.0 a0=1.02 a1=0.40 a2=0.10 pACD=5.19 sf=1.43 A=118.4 A=118.5 133 [208]
[215]: data by Dr.D.Alzheimer, Germany
[10]: data by R.Walter-Fincke, MD, and W.Bachmann, MD, Aschaffenburg, Germany
As new IOLs are introduced, this listing will be updated. Oculentis L-403 A=118.0 a0= 1.02 a1=0.40 a2=0.10 pACD=5.16 sf=1.41 A=118.4 A=118.7 14 [106]
[169]: data by Dr.Angel Lopez Castro, Madrid, Spain
Alcon AcrySof IQ ReSTOR Multifocal IOL models (Models SN6AD1, SN6AD3, MN6AD1), this IOL (Model SV25T0) provides an alternate option for clinicians to offer patients with the near add power of +2.5 D, with optimal vision at 53 cm and greater distance dominance in the energy distribution between near and far. [104]: data by Prof.Dr.V.Seiberth, Germany
AMO PS60 ANB A=116.7 a0=1.15 a1=0.40 a2=0.10 pACD=5.46 sf=1.65 A=118.7 A=118.9 18 [2]
Clin Ophthalmol. Visional RBAG A=120.2 a0=1.88 a1=0.40 a2=0.10 pACD=6.04 sf=2.28 A=119.7 A=120.5 64 [31]
Alcon, a Novartis Division. [107]: data by Dr.V.Rasch, Potsdam, Germany
[45]: data by Dr.S.Janssen, Belgium
The Clareon PanOptix IOL is an advanced trifocal IOL equipped with ENLIGHTEN Optical Technologya proprietary design that optimizes intermediate vision without compromising exceptional near and distance vision.4,5 Hear what surgeons are saying about the CLAREON PanOptix IOL. [111]: data by Dr.A.Schweiker, Pforzheim, Germany
[341]: data by Fredrick Lang MD, Cecanot, Dominican Republic
[127]: data by H.Geggle MD,Seattle, WA, USA
[124]: data by H.Cerri MD, Pittsburgh, PA, USA
Santen X-70 (Japan) A=118.9 a0=1.86 a1=0.40 a2=0.10 pACD=6.05 sf=2.24 A=119.6 A=119.9 78 [251]
Author links open the side of the single-piece IOL optic has been rendered nonreflective by a T. Nagata, Y. IshiiAdhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic single-piece IOL. [157]: data by Dr.G.Scharioth, Recklinghausen, Germany
[77]: data by Dr.Baha Toygar, Istanbul, Turkey
[289]: data by HSK Wiesbaden, Germany
[161]: data by Dr.K.Schneider, Mnchengladbach, Germany
A=118.0 a0=1.39 a1=0.40 a2=0.10 pACD=5.58 sf=1.78 A=118.9 A=119.3 180 [53]
[336]: data by Dr. Jean Philippe Seguin, Nevers, France
[155]: data by Prof.Dr.Grabner, Salzburg, Austria
1 review Write a review. [223]: data by Dr.J.Reiter, Landshut, Germany
Although not as intense as observed with the earlier 3-piece designs, pseudophakic dysphotopsia occurred in a few patients with the single-piece acrylic lens. [45]: data by Dr.S.Janssen, Belgium
Fritz Ruck HA-4-Q A=118.1 a0=1.14 a1=0.40 a2=0.10 pACD=5.29 sf=1.52 A=118.6 A=118.9 88 [102]
ZEISS TS43 - discontinued A=118.5 a0=1.13 a1=0.40 a2=0.10 pACD=5.19 sf=1.43 A=118.4 A=118.7 13 [6]
Oculentis LU-800 RZI A=116.0 a0= -0.11 a1=0.40 a2=0.10 pACD=4.10 sf=0.31 A=116.6 A=116.6 47 [108]
Surv Ophthalmol.
PLAY VIDEO Source: Alcon IOL Product Catalog 10-07_5. [275]: data by Dr.J.C.P.Lightvoet, Dokkum, The Netherlands
Schindler, Klaessen, Sendtner, Ingolstadt, Germany
[376]: data by Mr. Mark Cahill, Dublin, Ireland
AUROLAB FH5600AS (India) A=118.0 a0=0.68 a1=0.40 a2=0.10 pACD=4.92 sf=1.12 A=117.8 A=117.9 99 [288]
[73]: data by Dr.G.Felgemacher, Brilon, Germany
2018;12:2031-2037. Proprietary Precision Edge Design3,4 Proprietary edge curvature designed to help reduce PCO and edge glare.3,4 Superior Axial Stability5,6 Fibronectin helps bind the material to the capsule, anchoring the lens in place to help reduce PCO and improve stability.4-6 Optical Design with Proven Performance3,4,7,8 [227]: data by PD Dr.J.Weindler, Esslingen, Germany
[113]: data by R.Arleo, MD, Ithaca, Ithaca, NY, USA
[219]: data by Dr.Hans Klett, Herne, Germany
Bausch&Lomb INCISE MJ14 A=118.7 a0=1.35 a1=0.40 a2=0.10 pACD=5.51 sf=1.75 A=118.9 A=119.2 90 [354]
Please note also: the constant a0 of the Haigis formula may be positive as well as negative ! Secondary surgical interventions include, but are not limited to: lens repositioning, lens replacement, vitreous aspiration or iridectomy for pupillary block, wound leak repair, and retinal detachment repair. ZEISS Acri.Lyc 45S A=118.2 a0=1.20 a1=0.40 a2=0.10 pACD=5.41 sf=1.64 A=118.7 A=119.1 158 [214],[215]
[218]: data by Dr.Jens Klett, Herne, Germany
2008 Jun;246(6):787-801. doi: 10.1007/s00417-008-0779-6. [8]: based on data by L.Fry, MD, Garden City, KS, USA
[351]: data by Prof.Rakic, Dr.van Cauwenberge, Liege, Belgium
The following table may be downloaded and fed directly into the IOLMaster. [393]: data by Dres Becker, Cordero, Maruniak. Constants are given without any legal responsibility ! Lenstec LS-106 A=118.4 a0=1.61 a1=0.40 a2=0.10 pACD=5.84 sf=2.07 A=119.4 A=119.8 33 [2]
[90]: data by Dr.R.Wiedemann, Leipzig, Germany
[294]: data by Prof. Mark Packer MD, Eugene, OR, USA
[88]: data by Dr.F.Hhn, Ludwigshafen, Germany
Overall, the IOLs were easy to implant with no haptic or optic damage using a forceps or the Monarch injector. [102]: data by Fritz Ruck GmbH, Eschweiler, Germany
The following IOL constants were derived from clinical results with the ZEISS IOLMaster. Lens Implant SA60D3 Alcon Laboratories, Inc. Fort Worth, TX. [71]: data by Dr.S.Schmickler, Ahaus, Germany
[247]: data by Dr.Franc Salamun, Nova Gorica, Slovenia
[340]: data by Dr. Hanemoto, Mito, Japan
ZEISS CT SPHERIS 203(P) (XL Stabi, XL Stabi Sky) A=118.0 a0=1.05 a1=0.40 a2=0.10 pACD=5.23 sf=1.47 A=118.5 A=118.8 98 [37]
[300]: data by Prof. Dr. Mike Holzer, Heidelberg, Germany
[14]: data by P.Ursin, Nordhausen, Germany
[332]: data by Dr. Peter Stewart, Maroochydore, QLD Australia
P.Hoffmann MD(Castrop-Rauxel, Germany),
[256]: data by Prof.Dr.Andrzej Dmitriew, Poznan, Poland
(****): results based on highly myopic patients (mean axial lengths: 29.56 +/- 1.51 mm
[120]: data by Dr.L.Tschernjakov, Berlin, Germany
MBI PreciSAL 300A/300AC A=118.3 a0=1.26 a1=0.40 a2=0.10 pACD=5.39 sf=1.61 A=118.7 A=118.9 49 [388]
[162]: data by Dr.L.Frisch, Wiesbaden, Germany
(Alcon Laboratories, Inc.), and the Tecnis Z9000 (Advanced Medical Optics, Inc.). [25]: data by Dr.U.Reinking, Salzkotten, Germany
Rayner Superflex Asph 920 H A=118.0 a0=1.02 a1=0.40 a2=0.10 pACD=5.21 sf=1.41 A=118.3 A=118.5 169 [258],[300],[92],[363]
R.Tumer MD(Frankfurt, Germany),
[48]: data by Dr.A.Riel, Kiel, Germany
[34]: data by D.Rotmann, MD, Nordhorn, Germany
[236]: data by Dr.H.v.Wyk, Johannesburg, South Africa
[304]: data by Dr.H.Kaymak, Dr.D.Breyer, Dsseldorf, Germany
Aaren Scientific EC-3 A=118.2 a0=1.45 a1=0.40 a2=0.10 pACD=5.69 sf=1.89 A=119.1 A=119.4 35 [263]
[370]: data by Mr. Azfar W. Chohan, Isle of Man
[18]: data by P.Hoffmann, MD, Castrop-Rauxel, Germany
[327]: data by Mr. Say Aun Quah and Mrs. C.Gore, Manchester, UK
National Library of Medicine [305]: data by Dr.H.Morbelli, Albacete, Spain
If so, do not buy . [281]: data by Medicontur Ltd, Hungary
[150]: data by Dr.G.Savini, Bologna, Italy
AMO Tecnis Z9002 A=118.7 a0= -1.201 a1=0.102 a2=0.246 pACD=5.46 sf=1.67 A=118.8 A=119.0 1275 [109],[139],[140],[19],[103],[104],[72],[98],[232],[234],[239]
Moss Vision Optiflex MO/F-022 A=118.5 a0=1.37 a1=0.40 a2=0.10 pACD=5.61 sf=1.85 A=119.1 A=119.5 49 [369]
Bausch&Lomb LI61U Soflex A=118.0 a0= 0.272 a1=0.182 a2=0.163 pACD=5.28 sf=1.49 A=118.5 A=118.6 713 [40],[44],[100],[126]
Oculentis L-401 (47C) A=118.0 a0= 0.93 a1=0.40 a2=0.10 pACD=5.08 sf=1.33 A=118.3 A=118.5 98 [51],[86],[120]
In a review of 2630 consecutive cases operated on from January 2000 through July 2001, ease of IOL insertion and integrity of the haptic architecture were evaluated in a prospective fashion at implantation. [32]: data by Dr.V.Hessemer, Darmstadt, Germany
Domilens Domicryl M100 A=118.4 a0=1.56 a1=0.40 a2=0.10 pACD=5.72 sf=1.97 A=119.3 A=119.8 144 [227],[222]
[285]: data by Dr. Miguel Angel Perez, Gran Canaria, Spain
[64]: data by Dr.U.Weimantel, Frth, Germany
J.Strobel MD(Jena, Germany),
[235]: data by Th.Hofmann, Binningen, Switzerland
Results: [204]: data by Y.Kora, Hamamatsu, Japan
When did Woodrow Wilson marry his first wife? [27]: data by Dr.W.Lange, Prien, Germany
[107]: data by Dr.V.Rasch, Potsdam, Germany
In two further optimisations, the formula .
ISPAN is a registered trademark of Air Liquide America Specialty Gases LLC. [220]: data by Dr.Georg Leuschner, Garbsen, Germany
Europe / Middle East / Africa Rayner C-Flex 570 C A=118.0 a0=1.27 a1=0.40 a2=0.10 pACD=5.46 sf=1.68 A=118.8 A=119.1 149 [52],[73],[38]
M.Prskavec and M.Wirtitsch, Villach, Austria
[221]: data by Dr.B.Eckhardt, Landshut, Germany
Keith A.Gross MD, New Zealand,
MeSH Alcon, a Novartis Division The AcrySof Aspheric IOL (model SA60WF) is an ultraviolet-absorbing acrylic foldable single-piece IOL. [75]: data by Dr.U.Heuer, Hamburg, Germany
Hoya UV55SB (Japan)(**) A=117.6 a0=1.38 a1=0.40 a2=0.10 pACD=5.57 sf=1.68 A=118.6 A=118.5 109 [80]
Medicem WIOL-CF a0=2.36 a1=0.40 a2=0.10 pACD=6.55 sf=2.79 A=120.6 A=121.6 179 [358],[359],[366]
Oculentis LS-313 MF30 Japan A=118.0 a0=1.02 a1=0.40 a2=0.10 pACD=5.33 sf=1.55 A=118.5 A=118.3 55 [321]
[264]: data by Dr. C.Niederdellmann, Friedberg, Germany
[47]: data by Dr.Y.Walpuski, Kiel, Germany
Xcelens IDEA (HEMA26%) A=119.0 a0=1.78 a1=0.40 a2=0.10 pACD=5.96 sf=2.19 A=119.6 A=120.1 55 [9]
[383]: data by Dr. KIM Jun Heon, Seoul, South Korea
[393]: data by Dres Becker, Cordero, Maruniak. [212]: data by Dr.A.Ilkhani, Singen, Germany
[61]: data by R.Donoso, Chile
[259]: data by Dr. O.Cordero, Berlin, Germany
[171]: data by Dr.S.Sorokanich, Clarks Summit, PA, USA
Ciba memory lens CV232 A=119.0 a0=1.40 a1=0.40 a2=0.10 pACD=5.59 sf=1.82 A=119.0 A=119.5 61 [8]